TP 0620 is designed for easy and fast functional control of the major power semiconductors in the lab or on site.
Features
With the tp 0620 you measure the
breakdown voltage VD-VR
leakage current ID - IR
forward voltage drop VF, VT
on IGBT - Diodes - Thyristors and other components.
Easy to manipulate and use in the lab or in the field by technicians and engineers. It contains a current generator, high voltage generator, a gate drive and internal measuring circuits.
It is supplied with the necessary test leads, you don’t need anything else. LCD Display in 5 languages, (English, French, German, Italian, Spanish) for : Test to be carried out - Parameters - Test results
This is an extremely practical tool which will save you time in testing and reduce your costs.
By using this professional tool instead of a laboratory bench set-up you can increase your efficiency.
You can increase your proficiency by making reliable measurement and reduce repair time/down time by fast and accurate localization of faulty devices.
Forward voltage drop VF- VT
Applied current : 1 - 600 A
Voltage measure of : 0 - 10 V
Go-no go test : limits 0.0 - 9.9 V
Breakdown voltage VD - VR
Applied current: 0.1 - 10 mA
Voltage measurement : 50 - 2000V
Go-no go test : limits 50 - 1990V
Leakage current ID - IR
Applied voltage: 50 - 2000V
Measure of current: 0 - 10 mA
Test go-no go : limits 0.00 - 9.90 mA
Applications
Public Transportation
Maintenance and repair shops Trains, Underground, Trolley-busses, Tramways, Ship, and others
Heavy industry using rectifiers and converters
steel mills, mines, aluminium plants, galvanic-plastic and chlorine industry
Power electronics manufacturers
Drive, converter-inverter manufacturers, Repair shops (after sales), R & D