BF-6MB-SUSU with SSD HDC-AC technology can have long stability performance
The stainless steel shell allows it to be used in a clean environment
Use special techniques to reduce motor dust
Both the front and back sides are made of conductor material to prevent external induction charge
With over current leakage current detection, to ensure the safety of use
Input Voltage: DC24V (AC100~240V AC adaptor)
Capacity: 10VA
Output Voltage: ± 7,500V0-p
Ion Balance: Below ±5V (Distance: 300mm)
Decay time: Less 1.5 seconds (Distance: 300mm, with Maximum air speed)
Air Flow: 1.4~3.2m3/min
Air Speed: 0.8~1m/sec (Distance: 300mm center)
Ozone level: Less 0.006ppm (Distance: 150mm)
Available Environment: 0~40℃ / 15~85%RH (Without any condensation)
Filter: /
Signal Output: MOS FET Relay non voltage contact (NC Output)
(High voltage abnormal OFF)
Dimensions: 566×146×69mm (W×H×D)
Gross Weight: Approx. 3.3kg (with Bracket)
Materials: Body: SUS304, Emitter: Tungsten, Bracket: SUS
Front Louver cover: PC/ABS
Sound Level: 61dB(A) (Distance: 1m)
Accessories: Manual, AC Adaptor, Conductive wide angle louver,
Signal out cable
Optional part: Emitter unit, DNU-W85