The Model 50/12 is a DC-stable, high-voltage power amplifier featuring an all solid-state design for high slew rate, wide bandwidth, and low-noise operation. It is designed to provide precise control of output voltages in the range of 0 to ±50 kV DC or peak AC with an output current range of 0 to ±12 mA DC or peak AC.
The 4-quadrant, active output stage sinks or sources current to reactive or resistive loads throughout the output voltage range. 、This is essential to achieve the accurate output response and high slew rates demanded by reactive loads.
Features and Benefits
Four-quadrant output for driving capacitive loads
Closed loop system for high accuracy
Short-circuit protected for equipment protection
All solid-state design for maintenance free operation
DC-stable for programmable supply applications
Low output noise for ultra-accurate outputs
NIST-traceable Certificate of Calibration provided with each uni
CE compliant
Model 50/12 Specifications
Performance
Output Voltage Range:0 to ±50 kV DC or peak AC
Output Current Range:0 to ±12 mA DC or peak AC
Input Voltage Range: 0 to ±10 V DC or peak AC
Input Impedance: 25 kW, nominal (inverting/differential option 50 kW nominal)
DC Voltage Gain: 5000 V/V
DC Voltage Gain Accuracy: Better than 0.1% of full scale
Offset Voltage: Less than ±5 V
Output Noise: Less than 10 V rms*
Slew Rate (10% to 90%, typical): Greater than 350 V/µs
Small Signal Bandwidth (-3dB): DC to greater than 20 kHz
Large Signal Bandwidth (2% distortion):DC to greater than 1.4 kHz
Stability: Drift with Time Less than 50 ppm/hr, noncumulative
Drift with TemperatureLess than 100 ppm/°C
Voltage Monitor
Ratio: 1 V / 5000 V
DC Accuracy: Better than 0.1% of full scale
DC Offset Voltage: Less than ±4 mV
Output Noise: Less than 20 mV rms*
Output Impedance: 47 W
Current Monitor
Ratio: 0.5 V/mA
DC Accuracy: Better than 2% of full scale
Offset Voltage: Less than ±10 mV
Output Noise: Less than 30 mV rms*
Bandwidth (-3dB): DC to greater than 5 kHz
Output Impedance: 47 W
Features
High-Voltage On/Off
Local Individual push-button switches
Remote TTL compatible input. TTL high (or open) turns off high-voltage output. TTL low turns on highvoltage output.
Dynamic Adjustment: Graduated 1-turn potentiometer is used to optimize the AC response for various load parameters.
Current Limit/Trip:
Switch selectable for limit or trip. Graduated 1turn panel potentiometer is used to adjust limit or trip level from 0 to ±12 mA. Out of Regulation Status Indicator and Connnector:
Illuminates and TTL low is provided when unit fails to produce required HV output such as during current limit.
Limit/Trip Status Indicator and Connector:
An indicator will illuminate and a BNC will provide a TTL low when the high-voltage output is disabled due to the output current trip level, the detection of a high-voltage power supply fault, removal of one of the panels, or if the Model 50/12 is in an out of regulation status for greater than 500 ms.
Mechanical
Dimensions: 1473.5 mm H x 628.7 mm W 948.4 mm D (58.01” H x 24.75” W x 37.34” D)
Weight: 125-136 kg (275-300 lb)
HV Connector: High Voltage Connector
BNC Connectors: Amplifier Input, Voltage Monitor, Current Monitor, Remote High Voltage ON/OFF, Out of Regulation Status, Fault/Trip Status
Operating Conditions
Temperature: 0°C to 40°C (32°F to 104°F)
Relative Humidity: To 75%, noncondensing
Altitude: To 1524 meters (5000 ft.)
Electrical
Line: Voltage 180 to 250 V AC at 48 to 63 Hz
Power Consumption: 1800 VA, maximum
AC Line Receptacle: Standard 3-prong with integral fuse holder
Supplied Accessories
Operators Manual PN: 23459
Shorting BNC Cap PN: B3060
HV Output Cable PN: 43466
Line Cord, Fuses Selected per geographic destination