ELECTRICAL TEST EQUIPMENT CALIBRATOR

  • Product No:3200B
  • Manufacturer:Transmille Ltd.
  • The industry leading 3200A series provides by far the fastest and safest solution for calibration of Loop, RCD, PAT's and insulation testers. 

  • Traditional testing practices require many pieces of test equipment and exposure to hazardous voltages, with a typical multifunction tester taking up to 45 minutes to test.

  • Using the 3200A, calibration time can be dramatically reduced to under 15 minutes, all while increasing safety. Cost effective calibration can be put into practice easily, providing a fast return on investment.

  • A dedicated localized mains socket on the front panel provides direct connect for Loop and RCD testers, removing the need to make connections to the mains/line voltage using 4mm type test leads and crocodile clips. This important safety feature eliminates the risk of shock to the engineer as connections are made with standard mains/line plugs.

  • CONTINUITY TESTING

    Continuity Resistance
      Continuity Variable Range: 0.2Ω to 20Ω (0.01Ω Resolution)
      Continuity Fixed Outputs : 100Ω : 1kΩ
      Standard Accuracy : 1% ± 25mΩ
      High Accuracy (Option) : 0.25% ± 25mΩ

    Continuity Current Measurement (Into 1Ω)
      Range : 0 to 320mA (0.1mA Resolution)
      Accuracy : 1.3% ± 6 Counts             

  • INSULATION TESTING

    Insulation Resistance
      Range : 10kΩ to 2GΩ (10GΩ Option : 5%)
      Accuracy : 10kΩ to 5MΩ 0.3% (0.1% Option)
                       5MΩ to 2GΩ 3% (1% Option)
      Resolution : 10kΩ

      Max Volt/Power : 1.1kV or 1 WATT (15kV Option)

    Insulation Test Voltage Measurement
      Ranges : 50V, 100V, 250V, 500V, 1kV
                     (0.1V Resolution)
      Current Measurement : 0.5mA, 1mA
      Accuracy : 1% ± 8 Counts

    AC Voltage Output
      Range : 100V, 200V, 230V, 300V, 400V
      Accuracy : 0.2% ± 1 Counts          

  • RCD TESTING

    Time        Range : 20ms to 5s (10ms Resolution)
                    Accuracy : ± 0.7ms
    Current    Range : 3mA to 3A
                    Resolution : 0.01mA (to 200mA)
                                     : 0.1mA (to 1A) • 1mA (to 3A)
                    Accuracy : < 190ms 5% ± 20 Counts
                                   : up to 5s 1.2% ± 6 Counts
                    Timing Modes : Immediate & Zero Crossing
                    Current Modes : I, ½ I, 2I, & 5I
                    Display Modes : 0° and 180° Phase
    Duration  Range : 10ms to 5s
                    Resolution : 0.1ms   

  • LOOP TESTING

    Resistances
      0.05Ω, 0.1Ω, 0.22Ω, 0.33Ω, 0.5Ω, 1Ω, 5Ω, 10Ω, 100Ω, 1kΩ

      Resolution : 0.1mΩ(to 10Ω) ; 1mΩ (to 1kΩ)
      Accuracy : 0.5% ± 4mΩ

    Auto Loop (Option)
      Maximum Correction : 2Ω

      Resolution : 100μΩ

      Accuracy : ±18mΩ

      Measurement Current : 4A

  • PAT TESTING

    Earth Bond Resistance

      Values : See Loop Values
      Accuracy : 0.5% ± 4mΩ

      Resolution : 0.1mΩ (to 10Ω) : 1mΩ (to 1kΩ)

    Earth Bond Current Measurements

      Ranges : 100mA, 10A, 30A
      Resolution : 1mA, 10mA, 10mA
      Accuracy : 1.5% ± 6 Counts

    PAT Insulation Resistance

      Range : 30kΩ to 2GΩ (10kΩ Resolution)
      Accuracy : See Insulation Resistance

    PAT Leakage

      Ranges : 2mA, 4.7mA, 7.7mA (1uA Resolution)
      Accuracy : 1.5% ± 2 Counts

    PAT Leakage Test Voltage

      Range : 100V to 300V RMS (0.1V Resolution)
      Accuracy : 1.5% ± 9 Counts

    Load Testing

           Ranges : S/C, O/C & 0.13kVA
           Accuracy : 440Ω ± 5%        

  • PAT TESTING : FLASH (OPTION)

    Flash Test Voltage

      Class 1 : 1kV to 1.8kV (1V Resolution)
      Load Resistance : 600kΩ (2.5mA @ 1.5kV)
      Class 2 : 2kV to 3.6kV (1V Resolution)
      Load Resistance : 1.2MΩ (2.5mA @ 3kV)
      Accuracy (Class 1&2) : 4% ± 10 Counts

    Flash Current Measurement

      Range : 1mA to 3mA
      Resolution : 10uA
      Accuracy : 5%

  • BREAKDOWN TESTING (OPTION)

    Voltage   Range : 3kV • 12kV
                   Resolution : 10V
                   Accuracy : 0.5% ± 3 Counts

    Current   Range : 200uA • 2mA • 20mA
                   Resolution : 100nA • 1uA • 10uA
                   Accuracy : 0.5% ± 4 Counts (200uA)

  • LINE VOLTAGE MEASUREMENT

    Range : 200V to 260V
    Resolution : 0.1V
    Accuracy : 0.8% ± 6 Counts

  • GENERAL SPECIFICATIONS

    Line Power : 230V/110V 50Hz /60Hz
    Dimensions : 45 x 44 x 14cm • Weight : 10kgs
    Warm-up Time : Double the time last used to 20 minutes max.
    Interface : RS232 • USB (Via Adapter)