The directive coupling system used in the emitter section generates a good balance of positive and negative ions with minimal secular change for highly effective static elimination.
Multiple fan motors are provided, the airflow is continuously variable, and the airflow direction can be adjusted vertically. (all models)
The horizontal configuration of these models enables the elimination of static over a wide-ranging area, which makes them ideal for use in various applications including desktop and line use. (all models)
The self-adjusting function ensures an ideal balance between the positive and negative ions. (An ion balancer is built)
Model | BF-80 | BF-120 | BF-160 |
Input power supply | 100 to 120VAC / 200 to 240VAC(50/60Hz) switch-selectable | ||
Capacity | 50VA | 70VA | 90VA |
Output voltage | 4.5kVAC | ||
Ion balance | ±20 V or less | ||
Airflow | 8.8 m3 / min | 13.2 m3 / min | 17.6 m3 / min |
Ozone density | 0.01 ppm or less | ||
Operating Environment | 0 to 40℃ / 15 to 85% RH (no condensation) | ||
Filter | Pre-filter level(option) | ||
Main unit dimensions | 868×130×218 mm (W×H×D) | 1262×130×218 mm (W×H×D) | 1656×130×218 mm (W×H×D) |
Weight | 8500g(including stand) | 12000g | 16000g |
Noise level | 65 dB (A) |