The Trek Model 615-3 is a precision high-voltage AC/DC generator that can be used in constant voltage, constant current or external
amplifier mode. It is specifically designed to simultaneously provide the AC and DC operating potentials required to operate/control an
electrostatic charger roller and offer features such as four-quadrantoutput, high rejection of load current noise and three wave output
shapes.The Model 615-10 has the same features with a 20 kV peak-to-peak capability. Please refer to the Model 615-10 data sheet for more information.
Features and Benefits
Monitor and control photoreceptor charging current with very high accuracy
Four-quadrant output for driving capacitive loads
Short-circuit protected for equipment protection
Operator-selectable sine, square or triangle wave output shape
NIST-traceable Certificate of Calibration provided with each unit
CE compliant
615-3 Abridged Specifications
Output Limits (any mode)
AC Voltage (DC Bias is zero) 0 to ±5 kV DC or peak AC
AC Voltage + DC Bias 0 to ±5 kV peak
DC Bias (AC Voltage is zero) 0 to ±5 V DC or peak AC
AC Current (DC Current is zero) 0 to 5 mA, average. AC current average = (2) I peak / 3.14
AC Current + DC Current 0 to ±8 mA peak
DC Current (AC Current is zero) 0 to 8 mA DC
Frequency (Internal Generator) 100 Hz to 10 kHz
Additional Amplifier Specifications
Input Voltage Range ±5 V DC or peak AC
Gain for Noninverting Range Factory set for 1000 V/V, 500 V/V is available
Slew Rate (10% to 90%, typical) Greater than 80 V/μs
DC Voltage Gain Accuracy 0.5% of full scale
Large Signal Bandwidth (1% distortion) DC to greater than 3 kHz
Small Signal Bandwidth (-3dB) DC to greater than 10 kHz
Voltage Monitor
Scale Factor 1/1000th of the high-voltage output
DC Accuracy Better than 0.1% of full scale
Offset Voltage Less than 2 mV
Output Noise Less than 10 mV rms*
Output Impedance 50 Ω
Current Monitor
Scale Factor 1 V/ mA
DC Accuracy Better than 0.2% of full scale
Offset Voltage Less than 2 mV
Output Noise Less than 20 mV rms*
Output Impedance 50 Ω
Features
Internal AC Generator An internal AC function generator is used to produce the AC output voltage (Constant AC Voltage mode) or the AC load current (Constant AC Current mode).
Note: Not used in AMPLIFIER mode
Waveform Options Square, sine, or triangle
Frequency Range 100 Hz to 10 kHz
Amplifier Input Mode A front panel BNC connector which will process an external signal.
Constant Voltage/Constant Current Two 10-turn dials for precise settings.
Constant Current Range Select Selects current mode for 0 to 500 mA or 0 to 5 mA average.
DC Bias Adjustable from 0 to ±5 kV DC.
High-Voltage AC Output Limit Adjustable from 0 to 10 kV p-p for both Constant Current mode and Constant Voltage mode
Accuracy 5% of full scale
High-Voltage On/Off Local:Front panel switch. Remote:A TTL compatible input.
Master DC Switch Turns ON and OFF the DC generator
Master AC Switch Turns ON and OFF the AC generator
AC Voltage or Current Mode Selection
Local Operation:A front panel switch.
Remote Operation:A TTL compatible signal applied to the Mode Select input of the Remote Interface connector
Compliance Indicator A LED will illuminate during an over-voltage condition when operating in the Constant
Current mode or during an over-current condition when operating in the Constant Voltage mode.
Overload Indicator A red LED will illuminate when the output current limit is exceeded.
Mechanical
Dimensions 134 mm H x 432 mm W x 432 mm D (5.25" H x 17" W x 17" D)
Weight 24.9 kg (55 lb)
HV Connector Alden High Voltage Connector
Operating Conditions
Temperature 15°C to 35°C (59°F to 95°F)
Relative Humidity To 85%, noncondensing
Altitude To 3,048 meters (10,000 ft.)
Electrical
Line Voltage Factory Set for one of two ranges:104 to 127 V AC or 180 to 250 V AC,either at 48 to 63 Hz
Power Consumption 100 VA, maximum
Supplied Accessories
Operators’Manual PN: 23186
HV Output Cable PN: 43406
Line Cord Selected per geographic destination