The Trek Model 158A Charged Plate Monitor is the premier instrument to evaluate the performance of air ionization systems. It features a user-friendly large 7 inch screen that is active through either touchscreen control or corresponding function keys. The compact design supports superior data collection and data storage capability. The data is displayed in color and may be stored internally or can be easily transferred to a USB flash drive or other USB device.
A charged-plate assembly is required and is sold separately (6 inch charged-plate shown).
Touch screen or function key control
Long battery life
User-friendly compact design with superior data collection and storage capability
Unique color graphics chart display
PC memory card port for ample data storage and easy data transfer
Programmable start and stop voltage for (+) and (-) decay time ionizer tests
0.1 V plate voltage resolution
Compliance to IEC 61340-5-1 and ANSI/ESD STM3.1
NIST-traceable Certificate of Calibration provided with each unit
CE compliant units available
Monitored Voltage Range:0 to ±1100 V DC or peak AC
Bandwidth: (-3 dB) DC to 80 Hz
Zero Stability (referred toplate voltage)
Drift with Time (no incidention flow):Less than 6 V/minute
Drift with Temperature: Less than 10 mV/°C, noncumulative
Decay Mode Thresholds
Start Voltage: Programmable from 1 to ±1000 V in 1 V increments
Start Accuracy: Within ±1 V of programmed start voltage
Stop Voltage: Programmable from 0 to ±999 V in 1 V increments
Stop Accuracy: Within ±1 V of programmed start voltage or ±0.2 V if set less than or equal to 90 V
Decay Timer Resolution:0.1 sec., from 0.1 sec. to 999.9 sec., resolution 0.1 sec