RM-G8800 measuring the resistance between the two points by connecting the equipment grounding point and the zero potential point, so as to monitor whether the grounding resis tance is normally to reduce electrostatic discharge (ESD) and electromagnetic interference (EMI)
Test Range:0.1Ω~10Ω
Test Accuracy:±0.1Ω(≤1Ω) ±10%(1~10Ω)
Input voltage:DC24V 1A
Output port:LAN RJ45 RS232 3Pin DI/O
Alarm Range:1Ω~10Ω adjustable
Resolution:0.01Ω
Advantage:Wave filtering function
Size:120mm*110mm*31mm