Space charge measurement using the acoustic technique has become a common method for investigating dielectric properties of solid materials. Among various techniques, the Pulsed ElectroAcoustic (PEA) method has been used for various industrial applications, such as for the evaluation of high voltage insulation. Typical PEA systems can measure space charge profiles in the thickness direction of specimens. “PEANUTS system for 85C Test Chamber” is available to be used under such a high temperature/environment. The amplifier part of PEANUTS is set out of test chamber to avoid getting damage cause of high temperature as 85℃.
Feature 1) Non-destructive 2) High capability for the electrical noise avoidance. Since it can avoid electrical noise, measurement under high voltage application is possible. 3) Automatic repetitive measurement is available by software. 4) Reproducibility is excellent. 5) Easy operation, handling. It is only putting the sample between the two electrodes.
Specification
1)PEA Measurement unit (Amplifier separate type) #50-101-50A “Sensor part” is set in chamber, “Amplifier part” is set out of chamber.
1-1)Sensor part
Sensing Method Pulsed Electroacoustic Method
Specimen Dielectric materials
Specimen size Width: 20-50mm,
Thickness: 0.05-1.0mm,
Flat plate or film Resolution 25 ~ 30μm at Room temp
High Voltage 10 kV or less
Environment Sample temp. to 85℃
Dimension 250(W) x 200(D) x 150(H) mm
1-2)Amplifier part # 50-101-50B
Input voltage DC15V
Dimension 250(W) x 200(D) x 100(H) mm
2)Electric source of Amplifier #50-112-11 (Installed in rack)
Output Voltage DC15V
Input Source AC100V 1A
3)400Hz Pulse generator #50-211-02 (Installed in rack)
Output voltage 50, 100, 200, 400, 600 V
Output Frequency 400Hz
Pulse width 5ns (FWHM)
Input Source AC100V 1A
4)High Speed / High Voltage Power Supply #50-605-01 (Installed in rack)
Voltage range +/- 10kV
Response Speed 1kHz
Dimension 483(W) x 520(D) x 150(H) mm
Input Source AC100V 0.7A
5)PEA Analysis system
5-1) Computer OS: Windows 10, 64 bit (English version)
GP-IB board is installed Input Source
AC100V 4.25A
5-2)Analyzing Software PEANUTS # 50-301-01 (Ver.2.7.14)
Calibration for Charge Density, deconvolution, Electric field / Potential
5-3)Digital Oscilloscope #50-761- WR604Zi,4CH 400MH)(Installed in rack)
Band width 600MHz Channel
2ch Sampling rate 5GS/s Memory
12.5 Mpts / chi Dimension 260(W) x 340(D) x 152(H) mm
Input Source AC100V
6)Standard rack #50-901-11 Standard
JIS standard, 19inch rack Internal Dimension 549(W) x 740(D) x 900(H) mm